Reverse Time During Current Relay Performance to Support the Protection System Practicum
DOI:
https://doi.org/10.32497/eksergi.v18i2.3572Keywords:
Reverse Current Relay TimeAbstract
””Overcurrent Relay is one of the protection system tools in the electricity network. Overcurrent Relay works based on the increase in fault current that exceeds a certain safety value and a certain period of time. The type of relay that will be used in this test is the IDMT NX203A Overcurrent Relay. The purpose of this test is to get a good practicum module and to prove the inverted time relay characteristic curve according to British Standard BS142. In the test, the tool to be assembled is tested for its work function so that in data collection errors can be avoided while the relay on the module will be given a current setting of 2A; 3A; and 4A with TMS0.05; 0.5; and 1.0 which will be connected to a digital timer so that if the fault current exceeds the setting current, the relay will automatically give a signal and the digital timer will show the time when the current is cut off. The final result is a practicum module where each tool functions under normal working conditions and a graph of time against relay current for setting current 2A, fastest time 0.498s at 9A fault current and 0.05 TMS, longest time 12.991s at 4A TM fault current. . 1.0. Current setting of 3A for the fastest time is 0.572s at fault current of 9A and TM 0.05, for the longest time is 35.854s at fault current of 4A and TM 1.0. Current setting of 4A for the fastest time is 0.708s at fault current of 9A and TM 0.05, for the longest time is 55.979s at fault current of 5A and TM 1.0.References
Abdul Mu”™is, Sugianto. 2017.Perencanaan Sistem
Distribusi Listrik Pelaksanaan Proyek Apartemen. Program
Studi Teknik Elektro ”“ ISTN
Anaa Istimaroh, Nasrun Hariyanto, Syahrial, 2013,
Penentuan Setting Rele Arus Lebih Generator
dan Rele Diferensial Transformator
Unit 4 PLTA Cirata II, Jurnal Reka Elkomika
©TeknikElektro,Itenas,Vol.1,No.2, Februari 2013
Ali Akmal, Ketut Abimanyu, 2017, studi pengaturan relai
arus lebih dan relay hubung tanah timor 4 pada gardu induk
studi kasus: Gardu Induk Dawuan, vol.2 no. 1,Jurnal
Teknologi Informasi Dan Elektronika
Ananta S.D, 2015, Studi Koordinasi Proteksi Rele Arus
Lebih,Diferensial Dan Ground Fault Pada Pt. Linde
Indonesia, Cilegon, Jurusan Teknik Elektro
Fakultas Teknologi Industri
Institut Teknologi Sepuluh Nopember Surabaya
Ade Wahyu Hidayat, Herri Gusmedi, Lukmanu Hakim,
Dipride Despa,2013, Analisa Setting Rele Arus Lebihdan
Rele Gangguan Tanah pada
Penyulang Topan Gardu Induk Teluk Betung, Volume 7,
No. 3, September 2013, Jurnal Rekayasa dan Teknologi
Elektro
Affandi, Irfan. 2009. Analisa Setting Relai Arus Lebih dan
Relai Gangguan Tanah pada Penyulang Sadewa di GI
Cawang. Skripsi Program Studi Teknik Elektro
Kekhususan ElektroUniversitas Indonesia.
Chomarudin,Riki. 2018. Rele Proteksi pada Saluran
Transmisi dan Gardu Induk. Universitas Gajah Mada
Engla Pafela, Eddi H.,2017, Studi Penyetelan Relay Arus
Lebih (OCR) pada Gardu Induk Teluk Lembu Pekanbaru,
Teknik Elektro Universitas Riau. Jom Fteknik vol 4 no 1
Februari 2017
Hazairin, Samaulan. 2004. Dasar-Dasar Sistem Proteksi
Tenaga Listrik. Unsri.
Indra Roza1, AgusAlmiNasution, Rele Analisa Koordinasi
Setting Rele Mengurangi Daerah Padam
Pada Penyulang PE6 Di PT. PLN (PERSERO) Rayon
Kotanopan, vol 4 no. 2, 2022, Jurnal Teknik Elektro.
D.G. Agung Budhi, I.D Diyana Arjuna, Tjok Gede Indra
Partha, 2017, Studi Analisis koordinasi Over current
relay(OCR) dan ground fault Relay(GFR) pada recloser
penjulangan jaringan penebel, Teknologi Elektro vol. 16
no, 2 Mei-Agustus 2017
MisfaSusanto, Sitronella Nurfitriani Hasim, and Helmy
Fitriawan, Relay-Based Clustering Method for
Interference
Management in Heterogeneous Wireless Cellular
Network, JurnalTeknikElektro Vol. 13 No. 2 P-ISSN 1411
- 0059
Muhalan,Yanto Husodo Budi. Jurnal Analisa Perhitungan
dan Pengaturan Relai Arus Lebih dan Relai Gangguan
Tanah pada Kubikel Cakra 20 kV di PT. XYZ, hal 166.
ISSN: 1410-233
NX203A IDMT Over Current Relay User”™s Guide
Sanzarian, Yogi.2015. Koordinasi Rele Arus Lebih dan
Rele Gangguan Tanah Menggunakan Program Berbasis
Electrical Transient And Analysis Program (ETAP) Pada
Gardi Induk Bungaran Di PT. PLN. Politeknik negeri
Sriwijaya Hal 17
Sahi Aiyub, Zaman, Aulia Kasyfi, 2018, Penggunaan relai
arus lebih type sel 351A sebagai proteksi motor induksi 3
fasa, vol. 2 no. 1 2018, ISSN 25973959
Sarimun,Wahyudi.2012.Proteksi Sistem Distribusi Tenaga
Listrik. Jawa Barat:Garamond
TEMI TIMOTIUS D. NGEDI.2016.Pengggunaan Over
Current Relay Dalam System Tenaga
Listrik. UNIVERSITAS NUSACENDANA
Downloads
Published
Issue
Section
License
Authors who publish with this journal agree to the following terms:Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).