PENGONTROLAN TEGANGAN PADA PROTON EXCHANGE MEMBRANE FUEL CELL (PEM-FC) MENGGUNAKAN PARTICLE SWARM OPTIMIZATION DAN PID
Abstract
Keywords
Full Text:
PDFReferences
C. J. Hatziadoniu, A. A. Lobo, F. Pourboghrat, and M. Daneshdoost, “A simplified dynamic model of grid-connected fuel-cell generators,” IEEE Trans. Power Delivery, vol. 17, no. 2, pp. 467–473, Apr. 2002
C. Wang, Student Member, M.H.Nehrir, Senior Member, and H. Gao, Member.” Control of PEM Fuel Cell Distributed Generation Systems ”IEEE Transactionson Energy Conversion,vol.21,no.2, 2006
EG&G Technical Services, Inc. “Fuel Cell Handbook (Fifth Edition)”, U.S. Department of Energy, West Virginia, October 2000
El-Khattam, W., Salama M.M.A., “Distributed Generation Technologies, Definitions and Benefits”, Elsevier Electric Power Systems Research 71, pp. 119–128, Canada, January, 2004
Fuel Cell Hand Book, 5th edition (2000). EG & G Services Parsons, Inc. Science Application International Corporation.
Hala Rslan, Mahrous Ahmed, Mohamed Orabi, Mohamed Youssef, “Development of Grid Connected Power Conditioner System Compatible with Fuel Cell Applications”, IEEE International Symposium on Power Electronics for Distributed Generation Systems, pp. 935-941,Canada, October, 2010
Jong-Soo Kim, Gyu-Yeong Choe, Byoung-Kuk Lee, Jae-Sun Shim, “Advanced Interchangeable Dynamic Simulation Model for the Optimal Design of a Fuel Cell Power Conditioning System”, Journal of Electrical Engineering & Technology Vol. 5, pp. 561-570, Korea, July, 2010
Lasseter, R. Tomsovic, K., Piagi, P., “Scenarios for Distributed Technology Applications with Steady State and Dynamic Models of Loads and Micro-Sources”, CERTS Report, 2000
Ma Su Su Hlaing, “Design of a Low Loss Inverter for Fuel Cell Application”, SIM University, May, 2010
Pratama, A., “Optimalisasi Sel Surya Menggunakan Maximum Power Point Tracker Sebagai Catu Daya Base Transceiver Station”, Teknik Elektro ITS, Surabaya, Agustus, 2010.
Perdana, P., & Saputra, S. (2000). Perbandingan Metode Bat Algorithm Dalam Tuning Optimal Parameter Pss Di Single Machine Infinite Bus ( SMIB ). 3(2), 123–129. https://doi.org/10.32493/epic.v3i2.7624
Rahmawan, A., Budiman, A. H., & Hermawan, F. (2018). Disain sistem kontrol dan operasi untuk proton exchange membrane. Jurnal Energi Dan Lingkungan, 14(2), 75–80.
RashidM.H,“PowerElectronics Handbook”,AcademicPress, 2001.
Surya, P. P., Irawan, D., & Zuhri, M. (2018). Review and comparison of DC-DC converters for maximum power point tracking system in standalone photovoltaic (PV) module. Proceeding - ICAMIMIA 2017: International Conference on Advanced Mechatronics, Intelligent Manufacture, and Industrial Automation, 242–247. https://doi.org/10.1109/ICAMIMIA.2017.8387595
Yong Wang, Xu Cai, “DC Link Voltage Optimized Control for Efficient Residential Fuel Cell Converter”, Elsevier Electrical Power and Energy Systems 32,pp.1031–1036,China,February, 2010
DOI: http://dx.doi.org/10.32497/eksergi.v18i1.3209
Refbacks
- There are currently no refbacks.
Mechanical Engineering Department
Politeknik Negeri Semarang
Jl. Prof. Sudarto, SH., Tembalang, Semarang
Phone (024) 7478384; Fax: (024) 7472396
WA : 08112882883
Email: jurnal.eksergi@polines.ac.id
This work is licensed under a Creative Commons Attribution 4.0 International License.