Analysis of the Effect of Adding Insulators to Reservoirs Tank on Heat Losses as a Result of the Heat Exchanger System (Double Tube) for Water Heater

Authors

  • Nailul Atifah Universitas Pamulang
  • Dian Wiranda Tahami Universitas Pamulang
  • Fifit Astuti Universitas Pamulang

DOI:

https://doi.org/10.32497/jrm.v20i3.7119

Keywords:

heat loss, insulator, thermal efficiency, temperature, waste heat

Abstract

Air Conditioners release heat to the environment through a condenser and contribute to global warming. This can be minimized by utilizing exhaust heat as a source of water heating energy. This study aims to determine the effect of adding insulators to reservoir tanks on the temperature of the water that has been heated. This research was carried out by installing a double tube heat exchanger between the  compressor and the condenser to transfer heat from the refrigerant of the air conditioner to the water. The volume of water used is 10 liters and 15 liters and the condition of the reservoir tank is insulated and the tank is uninsulated. The results showed that the water temperature in the reservoir tank fitted with an Armaflex insulator was 63.4oC at a water volume of 10 L and 60.3oC at a water volume of 15 L while the water temperature in a reservoir tank without an insulator was 57.7oC at a water volume of 10 L and 52.3oC at a water volume of 15 L. The heat loss of conduction in the insulated reservoir tank at the 50th minute was 3.94 kJ for a volume of water of 10 L and 3.70 kJ for a volume of water 15 liters, while the heat loss of conduction in a reservoir tank without an insulator is 2,404.46 kJ for a volume of 10 liters of water and 2,129.66 kJ for a volume of 15 liters of water. The use of Armaflex insulators in reservoir tanks results in thermal efficiency of more than 95% for 10 liter and 15 liter water volumes, but as the water temperature increases to the 50th minute, the efficiency decreases but is still above 95%. Meanwhile, the uninsulated reservoir tank provides a much lower thermal efficiency, which is 27.22% and 25.57% for the water volume of 10 liters and 15 liters respectively in the first 5 minutes of air conditioning operation, and continues to decrease to 1.88% and 2.30% in the 50th minute. This shows that the use of Armaflex insulators in reservoir tanks exhibits higher water temperatures, has a very significant effect in reducing heat loss to the environment, and higher thermal efficiency than non-insulated reservoir tanks.

References

[1] S. Wiriyasart and S. Kaewluan, “Waste heat recovery of air conditioning on thermal efficiency enhancement of water heater,” Therm. Sci. Eng. Prog., vol. 47, no. July 2023, p. 102296, 2024, doi: 10.1016/j.tsep.2023.102296.

[2] S. Vyas, R. Thamke, N. Tanwar, D. Waghela, and S. Khetree, “A Review of Waste Heat Recovery from Air Conditioning System,” vol. 11, no. 04, pp. 152–157, 2022.

[3] C. Analysis et al., “Energy Recovery in Air Conditioning Systems : Comprehensive Potential Recommendations,” 2021.

[4] Z. Liu et al., “A high e ffi ciency electric heater based on dual-helical tube and screw-tape for instant water heating,” Appl. Therm. Eng., vol. 160, no. March 2018, p. 114018, 2019, doi: 10.1016/j.applthermaleng.2019.114018.

[5] H. Hosseini, M. M. A. Ashrafi, Z. Asadi, and D. D. Ganji, “Case Studies in Thermal Engineering Development in household water heaters by replacing the shell and tube heat exchangers by inclined flat ones having rectangular fins,” Case Stud. Therm. Eng., vol. 28, p. 101490, 2021, doi: 10.1016/j.csite.2021.101490.

[6] Z. Wang, F. Yang, D. Fu, L. Ma, and Z. Duan, “Case Studies in Thermal Engineering Economic and heating efficiency analysis of double-shell downhole electric heater for tar-rich coal in-situ conversion,” vol. 41, no. March 2022, 2023, doi: 10.1016/j.csite.2022.102596.

[7] G. B. Abdelaziz et al., “Energy saving via Heat Pipe Heat Exchanger in air conditioning applications ‘ experimental study and economic analysis ,’” J. Build. Eng., vol. 35, no. November 2020, p. 102053, 2021, doi: 10.1016/j.jobe.2020.102053.

[8] H. Kambli, D. Padwal, and Y. Kudale, “Utilization of Waste Heat from an Air Conditioning System,” pp. 1142–1152.

[9] A. Sarin, A. Goel, T. Sharma, A. Misra, and S. Tyagi, “Effective Utilization of Condenser Heat of a Refrigerator in a Heating Chamber,” vol. 7, no. 12, pp. 170–173, 2017.

[10] H. Sonawan, P. Saputro, and I. M. Kurniawan, “Utilization of air conditioner condenser as water heater in an effort to energy conservation,” vol. 1, pp. 4–7, 2018.

[11] D. Yudhy Kurniawan, “Pengembangan Penyimpan Air Panas Pada Sistem Hibrid Solar Thermal Air Conditioning,” Elem. J. Tek. Mesin, vol. 6, no. 2, pp. 69–76, 2019.

[12] H. Basri, E. Diniardi, and A. I. Ramadhan, “Design of Water Heating By Utilizing Waste Heat of Air Conditioner,” pp. 89–96, 2021.

[13] D. S. Amit Choudhari, Aditya Rane, Shamir Talkar, Pawan Rayan, “Designing and Prototyping for Conservation and Effective Utilization of Waste Heat from Air Conditioner,” Mater. Sci. Eng., 2020.

[14] E. Julianto and M. Iwan, “Design And Test The Performance Of The Water Heater By Utilizing The Exhaust Heat Of ThE,” vol. 15, no. 2, pp. 707–717, 2024, doi: 10.21776/jrm.v15i2.1494.

[15] Z. Muhamad, “Conditioning (AC)"”, [Online]. Available: http://artikel.ubl.ac.id/index.php/PKM/article/view/969/1306

[16] H. Poernomo, “Analisis Karakteristik Unjuk Kerja Sistem Pendingin (Air Conditioning) yang Menggunakan Freon R-22 Berdasarkan Pada Variasi Putaran Kipas Pendingin Kondensor,” Politek. Perkapalan Negeri Surabaya, vol. 11, no. 2, p. 124, 2015, doi: 10.54378/bt.v11i2.104.

[17] M. F. Rabbani and M. Habibuddin, “Rancang Bangun Pemanas Air Dengan Proses Pemanfaatan Panas Refrigeran Ac Menggunakan Horizontal Tube,” pp. 1–89, 2021.

[18] H. Hendradinata, F. Irawan, and ..., “Rancang Bangun Water Heater Dengan Memanfaatkan Panas Air Conditioning,” PETRA J. Teknol. …, vol. 5, no. 2, pp. 43–49, 2018, [Online]. Available: https://jurnal.polsky.ac.id/index.php/petra/article/download/172/166

[19] A. K. Najarudin, “Air, Analisa Termal Tangki Heater, Dengan Media Isolator Serbuk Batang Pohon Kelapa Pada Solar Water,” 2019.

[20] S. Hartono Budi Santoso, Agung Harjatmo, Arya Wulung, “Pembuatan Solar Collector Sistem Siklus Terbuka Dengan Alat Kontrol Berbasiskan Mikrokontroller ATMEGA 8535,” Yogyakarta IST AKPRIND Yogyakarta, 2008.

[21] D. Bergman, Lavine, Incropera, Introduction to Heat Transfer (sixth edition). New York : Wiley, 2011.

[22] Nazaruddin and Iskandar, “Pembuat Tangki Penyimpan Air Panas Tenaga Surya Menggunakan Bahan Serbuk Gergaji Batang Kelapa Sebagai Isolator,” Tek. Mesin ITM, vol. 2, no. 2, pp. 85–91, 2016.

[23] N. Atifah, B. Herlambang, E. T. Astuti, Y. Mulyana, and P. Sebayang, “Analisis Perpindahan Panas Pada Water Jacket Di Ruang Bakar Primer Incinerator Sampah Kota,” J. Tek. Mesin Cakram, vol. 3, no. 2, p. 63, 2020, doi: 10.32493/jtc.v3i2.7519.

[24] A. D. Wicaksono, Suwandi, and T. A. Ajiwiguna, “Pengaruh Bahan Insulasi Terhadap Perpindahan Kalor Pada Tangki Penyimpanan Air Untuk Sistem Pemanas Air Berbasis Surya,” e-Proceeding Eng., vol. 4, no. 3, pp. 3845–3852, 2017.

[25] G. Pikra, A. Salim, T. Admono, and M. I. Devi, “A Nalisis R Ugi - Rugi P Anas P Ada T Angki P Enyimpan P Anas Dalam S Istem P Embangkit L Istrik T Enaga M Atahari,” vol. 01, no. 1, pp. 13–18, 2010.

[26] J. P. Holman, Perpindahan Kalor cetakan ketiga. Jakarta: Penerbit Erlangga. 1993.

Downloads

Published

2025-12-30

How to Cite

Nailul Atifah, Dian Wiranda Tahami, & Astuti, F. (2025). Analysis of the Effect of Adding Insulators to Reservoirs Tank on Heat Losses as a Result of the Heat Exchanger System (Double Tube) for Water Heater. Jurnal Rekayasa Mesin, 20(3), 369–378. https://doi.org/10.32497/jrm.v20i3.7119