ANALISA KEBOCORAN FUEL SUPPLY PUMP PADA UNIT EXCAVATOR PC 135F-10M0 DI PT XYZ
DOI:
https://doi.org/10.32497/jmeat.v3i2.6662Abstract
The fuel system utilized in a unit is a crucial system, serving as the fuel supplier to the unit to start the engine. If the engine fails to start, one possible cause is a malfunctioning or damaged component of the fuel system, resulting in the high-pressure fuel not reaching the common rail. Consequently, the fuel is not supplied to the high-pressure common rail, leaving the engine without the required fuel supply. The outcome of this research is to identify and analyze the cause of the fuel supply pump component leakage in the excavator PC 135F-10M0 unit, with symptoms of the return hose to the tank being trapped by a clamp. Careless operation led to a wooden rod protruding into the bottom cover of the unit, puncturing and affecting the clamp on the fuel return hose to the tank.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Copyright of articles that appear in Journal of Mechanical Engineering and Applied Technology belongs exclusively to Penerbit Jurusan Teknik Mesin Politeknik Negeri Semarang. This copyright covers the rights to reproduce the article, including reprints, electronic reproductions, or any other reproductions of similar nature.