ANALISIS PENCAHAYAAN BUATAN DI RUANG KELAS LANTAI 2 GEDUNG SEKOLAH C (SC) POLITEKNIK NEGERI SEMARANG
ANALISIS PENCAHAYAAN BUATAN DI RUANG KELAS LANTAI 2 GEDUNG SEKOLAH C (SC) POLITEKNIK NEGERI SEMARANG
DOI:
https://doi.org/10.32497/bangunrekaprima.v12i1.7510Keywords:
Artificial Lighting, Classroom, Lux Meter, Lighting StandardsAbstract
Adequate lighting is crucial for supporting comfortable and effective classroom learning. This study evaluated the artificial lighting levels in a second-floor classroom on the C Building of Semarang State Polytechnic using a digital luxmeter. The research method used was to measure artificial lighting locally and generally. The final measurement results were compared to SNI 03-6575-2001, which requires a minimum value of 350 lux for classrooms. The measurements showed that most points had lighting values below 200 lux, indicating that the lighting did not meet the standard. The low lighting levels were caused by several malfunctioning lamps and uneven light distribution due to suboptimal fixture layout and room reflectance. These findings indicate the need for lighting system improvements to enhance visual comfort and support the learning process.
References
Dewi, R., & Arifin, M. (2020). Pengaruh pencahayaan terhadap kenyamanan belajar di ruang kelas. Jurnal Teknik Sipil, 18(2), 45-57.
Hendrawan, B., Kusuma, R., & Rahayu, T. (2023). Simulasi distribusi cahaya dalam ruang kelas menggunakan pemodelan komputer. Jurnal Rekayasa Bangunan, 25(1), 67-79.
Hidayat, T. (1986). Pengukuran Kinerja: Pengukuran Efektivitas dan Efisiensi. Jakarta: Lembaga Penerbit FEUI.
Illuminating Engineering Society (IES). (2021). Lighting Handbook: 11th Edition. IESNA.
Lechner, N. (2020). Heating, Cooling, Lighting: Sustainable Design Methods for Architects. John Wiley & Sons.
Milaningrum, D. (2021). Evaluasi tata pencahayaan ruang kelas terhadap kenyamanan visual mahasiswa. Jurnal Arsitektur dan Desain Interior, 12(3), 55-68.
Patty, F.A., et al. (1967). Industrial Hygiene and Toxicology. New York: Interscience Publishers.
Rahmawati, S., & Prabowo, H. (2019). Analisis kualitas pencahayaan ruang kelas terhadap efektivitas belajar mahasiswa. Jurnal Arsitektur dan Lingkungan, 14(1), 30-42.
Saputri, L. D., Sudarma, I. M., & Wibisono, A. (2021). Evaluasi pencahayaan buatan di lingkungan pendidikan menggunakan standar nasional dan internasional. Journal of Building Performance, 22(3), 78-92.
Suryadi, A., Nugroho, T., & Wijaya, R. (2022). Pemanfaatan sensor cahaya otomatis dalam efisiensi pencahayaan ruang kelas. Jurnal Teknologi Terapan, 19(4), 120-134.
Standar Nasional Indonesia (SNI) 03-6575-2001. Tata Cara Perancangan Sistem Pencahayaan Buatan di Bangunan. Badan Standardisasi Nasional (BSN).